• Mass Air Flow Sensor
    LOCATION:

Air flow sensors alternate to Honeywell AWM720P1/AWM700 Series
+86 18854156199 
+86 18854156199 
cindy@rainbowtechnology.cn

Learn more about product details

PRODUCT DESCRIPTION


Mass airflow sensor & mass flow meters alternate to Honeywell AWM720P1, AWM700 Series.

12SLPM, 20SLPM, 35SLPM, 50SLPM, 100SLPM, 150SLPM, 200SLPM, 300SLPM, 500SLPM

Analog output or I2C output.


1. Introduction
The S4000 mass airflow sensor (also called a flow meter) series is fabricated using a micro-electromechanical system (MEMS) flow sensor chip. It is suitable for the measurement of clean and relatively dry gases for various purposes. It realizes the digitization, intelligence and high safety of the equipment, and has the innovation of traditional industries. Function and improvement; a wide range of flow ranges meet the flow measurement requirements of different equipment in the industry. High sensitivity, high reliability, high stability and low cost can promote the industry to develop energy-saving and intelligent. 

The S4000 series is based on a MEMS flow sensing unit, high-precision digital processing and calibration circuit (MCU), integrated high-resolution delta-sigma A/D converter and logic with internal calibration and MCU processor. The sensing signal is effectively collected in real time, and the accurate flow signal is obtained, and the corresponding compensation algorithm is processed internally, so that no external calibration compensation is required, and high-precision flow output can be ensured; the friendly digital output communication mode can be used by the user. It is very convenient to get the corresponding data information; the product application range is very broad.
 
2. Features
Wide flow range 12SLPM-500SLPM 

High precision (1.5% F.S accuracy) 

Linear output and temperature compensation 

Maintain long-term stability with minimal zero drift 

Solid-state sensing core (no surface void or fragile membrane), anti-blocking and pressure shock 

Analog output (1 to 5 V) (I2C output is also available) 

Fast response time (20ms response time)
 
3. Application
Ventilator 

oxygen machine 

Gas mask and respirator 

Sprayer 

Continuous positive airway pressure (CPAP) device 

Anesthesia delivery 

Leak detection 

Spectrometer 

Mass flow controller 

Environmental climate control 

Fuel cell control


4. Maximum rating

Working temperature: -25 ° C to 85 ° C

Storage temperature: -40 ° C to 90 ° C 

    Humidity: 0~100%RH*

  Impact resistant 100 g

The sensor is resistant to condensation*


5. Specification


Electrical characteristics

Test conditions: VIN = 12 ± 0.01 VDC, Ta = 25 ° C. Relative humidity: 40% <relative

humidity <60%

Maximum operating temperature range -25°C to +85°C


Flow range(1)

Unit2)

Maximum flow rate(m/s)

S4003V

0-12

SLM

0.527

S4004V

0-20

SLM

0.877

S4005V

0-35

SLM

1.535

S4100V

0-50

SLM

2.193

S4101V

0-100

SLM

4.387

S4102V

0-150

SLM

6.58

S4103V

0-200

SLM

8.773

S4104V

0-300

SLM

13.16

S4105V

0-500

SLM

35.5


Specifications

Minimum

Default

Maximum

Unit

Supply voltage

8

12

24

VDC

Supply current

30


20

mA

Analog voltage

output (3)

1


5

VDC

Zero voltage

0.95

1

1.05

VDC

Zero drift

0.2

%F.S

Resolution (4)

0.1

%F.S

load

100

KΩ

Accuracy

1.5

2

%F.S

Response time

20

30

mSec

Overall material

Silicon carbide, epoxy resin, polyphenylene sulfide, FR4,

silicon as a seal


1. Customizable range between 10SLM and 500SLM

2. SLM: Standard liters per minute. Standard conditions: 0 ° C and 1 atmosphere

3. In addition, the two-way airflow test can be customized, and the analog output is  correspondingly changed. F(min)—F(max) corresponds to 1-5V output, and 0 flow  corresponds to 3V;

4. Includes temperature drift and linearity error


6. Linear Output


1. The unidirectional airflow mode: (calculation formula)
Flow = [(VOUT -1 V) / 4 V] × full scale flow
For example: S4103V has a full-scale flow of 200 SLM. When the output voltage is  read at 2.5V,
the instantaneous flow rate is [(2.5V-1V) / 4V × 200 SLM] = 75 SLM

MEMS Medical Flow Sensor alternative to Honeywell


2. Two-way airflow mode: (calculation formula)
Forward flow = [(VOUT -3 V)/2 V] × full scale flow
Reverse flow = [(3 V- VOUT)/2 V] × full scale flow